ASTM B280 · SI 6464 · ILAC

Copper Tubing · Israeli Gas Infrastructure · Compliance-First

Tested and work-ready copper tubing for Israeli gas infrastructure

We supply ASTM B280 copper tubing that arrives clean, nitrogen-purged, sealed, and fully documented. Every tube is tested, certified, and ready for installation.

UNS C12200≥99.9% CuN₂ PurgedILAC-Accredited

The need

Israel is building at scale. Gas infrastructure must keep up.

Israel's intensive and ongoing construction demands reliable gas infrastructure that will serve for many years. To ensure long-term durability, copper tubing must arrive clean, dry, and free of internal contamination.

To meet the strictest standards for safety and pressure resistance, tubing must be internally protected from residual processing oils, oxidation, and moisture — the primary factors that compromise gas valves, regulators, and pipe fittings over time.

As gas infrastructure suppliers, we are committed to delivering quality product — tubing that protects downstream components and keeps gas accessories functioning reliably long after installation.

Internal cleanliness

Residual processing oils and abrasion particles can compromise valve orifices and regulator seats. Proper cleaning ensures gas-system tolerances are met from day one.

Oxidation prevention

Copper oxidizes rapidly during storage and transport. Nitrogen purging and sealed ends protect the internal surface, preserving tube integrity throughout the supply chain.

Moisture protection

Unsealed tubes absorb ambient humidity, leading to corrosion at fittings and control devices. Factory sealing neutralizes this risk before the tube leaves the plant.

Full documentation

Material certifications and traceability documents are essential for regulatory submissions. Every tube must arrive with the paperwork needed to demonstrate compliance.

The solution

Tubes ready for installation. Delivered with documentation.

We work with verified manufacturers under a defined quality specification aligned with ASTM B280 and Israeli regulatory requirements. Every tube we supply has been internally cleaned, nitrogen-purged, end-capped, and comes with full material and compliance documentation.

This is tubing that meets the highest standards and arrives with full certification. The specification covers the internal condition of the tube — the critical part in gas and refrigeration applications.

✓ Tested and ready for installation.

Product specification

StandardASTM B280
AlloyUNS C12200
Purity≥ 99.9% Cu
Internal treatmentN₂ Purged
End conditionSealed & protected
Lab verificationILAC-Accredited
DocumentationFull traceability
01

High-purity alloy — UNS C12200

Phosphorus-deoxidized copper with ≥99.9% purity. Specified for gas and refrigeration applications where standard copper grades introduce risk of off-gassing or corrosion.

02

Nitrogen purge — internally clean and dry

Tubes are internally flushed and held under nitrogen before sealing. This process neutralizes residual moisture and prevents oxidation from manufacture through to installation.

03

Sealed ends — integrity maintained in transit

Both ends are mechanically capped before shipping. The internal condition at the factory is the internal condition on site. No re-cleaning required before installation.

04

Complete documentation package

Each shipment includes mill test reports, material certifications, ILAC-accredited lab results, and traceability documents aligned with Israeli regulatory submission requirements.

05

Verified ASTM B280 compliance

Compliance is documented and verifiable, not merely declared. Lab results from an ILAC-accredited facility cover mechanical properties, dimensional tolerances, and internal cleanliness.

06

Alignment with SI 6464 requirements

Supplied with awareness of Israeli standards requirements. Documentation structure is prepared to support regulatory submissions through the Standards Institution of Israel.

Why it matters

The right tube specification reduces risk at every stage of the project.

Faster regulatory approvals

Complete documentation arrives with the material. Inspectors can verify compliance without requesting additional paperwork or re-testing.

Protection of valves and regulators

Clean, dry tubing eliminates the primary cause of premature failure in pressure regulators and gas control valves — contamination from the supply chain.

Reduced installation risk

Installers work with tubing that has a documented internal condition. Site flushing procedures can be simplified because cleanliness is already verified.

Long-term system reliability

Infrastructure built with specified-grade tubing performs predictably over its design life. Unexpected failures from material quality are effectively eliminated.

Who it's for

We work with professionals for whom compliance is not optional.

  • Licensed gas installers — residential and commercial
  • Gas infrastructure and pipeline contractors
  • HVAC and refrigeration engineering companies
  • Technical importers and industrial distributors
  • Procurement teams requiring documented compliance

Compliance and verification

Every claim is documented. Every document is verifiable.

Manufacturers

Verified supply chain

We work exclusively with manufacturers that have auditable quality systems. Supplier qualification is based on demonstrated production capability and documentation standards, not price.

Testing

ILAC-accredited laboratories

Material properties are tested by internationally accredited laboratories. Results are traceable, reproducible, and accepted by Israeli regulatory authorities under the International Track.

Standards

Israeli market alignment

Documentation is structured with awareness of SII requirements and Israeli customs compliance. Supplied materials are prepared to support Maslul Plus submissions and port release.

Contact us

We deliver confidence.

Contact us for technical specifications, compliance documentation, and product availability. We respond to technical inquiries with complete information — no unnecessary sales process.

Request specifications

ASTM B280 · UNS C12200 · ILAC-Accredited · SI 6464 · N₂ Purged · Full traceability